RODUCT PARAMETERS:

Output power: 5W-200W
Maximum output current: 45A
Maximum output voltage: 12V
Power display: Battery icon on the screen
Charging port: Type-C Port
Resistance of atomizer: 0.1 ohm -3 ohm
Battery specification: 7.4V, external double battery 18650
Display screen:1.08 inch, TFT color screen
Operating temperature:0℃~45℃
Storage temperature:-20℃~60℃
Relative humidity: 45%RH~75%RH
Cooling mode: Natural cooling

INSTRUCTIONS:

  1. After powering on the device, the screen will light up and
    be operable aer displaying the power-on animation. The
    default mode is SMART mode aer power on.
  2. Power on: Press the Fire button 5 times in a row within 2s,
    and the device will display the power on animation and
    enter the standby mode.
  3. Shutdown: Press the Fire button 5 times within 2 seconds,
    the device will display the shutdown animation and then
    turn o the screen.
  4. Power Adjustment: Click “+” or “-” to adjust the power with 5-200W cycle, and long press the button to enter the fast adjustment mode.
  5. Temperature Adjustment: In TC mode, click “+” or “-” to adjust the temperature, the temperature step is 5°F/1°C, cycling from 100’C to 315°C.
  6. SMART mode: The battery box matches the optimal output power range according to the atomizer resistance value, and you can adjust the output power within the optimal power range through the adjustment key;(1)When the coil resistance value is 0.10-0.22Ω, the recommended power is 78W, and the power adjustment range is 78-80W;
    (2)When the coil resistance value is 0.23-0.500, the recommended power is 55w,and the power adjustmentrange is 55-60W.
  7. Normal Mode: In Normal mode, the device outputs the regular power state corresponding to this coil.
    (1)When the coil resistance value is 0.10-0.22Ω, the recommended power is 74W, and the power adjustment range is 74-77W;
    (2)When the coil resistance value is 0.23-0.50Ω, the recommended power is 52W,and the power adjustment range is 52-54W.
  8. ECO Mode: The device enters the power saving mod when entering the ECO mode in the settings.
    (1) When the coil resistance value is 0.10-0.22Ω, the recommended power is 7Ow, and the power adjustmer range is 70-73W;
    (2)When the coil resistance value is 0.23-0.50Ω, the recommended power is 48W,and the power adjustmen range is 48-51W.
  9. CUSTOM Mode: In this mode, you can freely adjust the power you need, which is especially suitable for produts like RDA/RBA/RTA/RDTA Atomizer.
    Friendly reminder: please pay attention to the recommended power range for the coil’s resistance to avoid damaging the coil and incurring losses.
  10. Entering the menu: Press the Fire button 3 times within 2s to enter the setting status.
  11. Switch the working mode:
    Press the Fire button 3 times in a row within 2s to enter the setting status;
    The cursor stays at the upper le working mode, press “+” or “_”to select the mode;
    Selectable working modes include: ECO/NOR-
    MAL/SMART/CUSTOM/TC.
  12. Smoking puffs clear:
    Press the Fire button 3 times within 2s to enter the setting status;
    Press Fire button to switch cursor and stay at PU display;
    Press “+” or “_” to clear the current value;
    Press “+” or “_” again to restore the current value.
  13. Change RGB Light:
    Into the menu, select option “LIGHT” via “+” or “_” button, the press fire button into tehe option page, select RGB effect option by button. There are 6 options:
    (1) COMET
    (2)FUSION
    (3)LUNA
    (4)NEBULA
    (5)NOVA
    (6)OFF
    (7)EXIT
  14. A-Lock: Switch the A-Lock button to lock or unlock device. When the device locked, fire button and “+””-” will not working until unlock device.
  15. Tips and protection:
    When atomizer resistance is<=0,08ohm, the screen displays a short-circuit prompt for 2 seconds.
    When battery voltage before output is < 3.2V or during output< 2.8V, the device stops output, and the screen displays a low voltage prompt for 2 seconds.
    When mainboard temperature before output is > 65℃ or during output > 85℃, the screen displays an overheating prompt for 2 seconds.
    When no atomizer is connected or atomizer resistance is >=2.2ohm, the screen displays a no atomizer prompt for 2 seconds.
    When a single pu duration exceeds 10±1s, the device stops output, and the screen displays a timeout prompt for 2 seconds.
  16. Brightness control:
    In the menu screen, select the BRlGHTNESS entry port to enter the BRlGHTNESS display screen.
    This interface adjusts the brightness by “+” and “-” keys, and is confirmed by fire key. Aer confirming, enter the default interface of selecting brightness.
  17. Product version information:
    (1) In the menu interface, select About to enter the About interface.
    (2)Aer entering this interface, lNFO will display product information.
  18. Restore factory settings
    (1)Aer selecting RESET, enter the restore factory settings.
    (2)The sub-interface provides only the 2 options:
    CONFIRM and BACK.
    (3)Select CONF|RM to indicate that the operation is confirmed and the device performs a settings reset and reboots automatically.
    (4) Aer entering this interface, INFO will display product information.
Related posts
Product parametersOutput power: 5W~200WMaximum output current: 45AMaximum output voltage: 12VPower...
INSTRUCTIONS 1. Inserting battery cell: The device flash "Geok vapor" one time and then screens...
INSTRUCTIONS 1. Power-on: Display power-on animation after installing battery, then the display...
INSTRUCTIONS 1. Powered: After power on display after the boot animation screen. 2. Turn on:...

Sharing is caring!