1.Overview
2. Dimension: 89.5x54x25mm
3. Specifications:
4. Battery Protection Functions:
A. Battery Reverse Protection
B. Timeout Protection
C. Over Temperature Protection
D. Output Over Current Protection
E. Over Charging Protection
F. Over Discharging Protection
G. Shortage Protection
H. Balanced Charging
5. VOOPOO Alpha Kit Operating Instructions:
ON/OFF:
Press fire button 5 times continuously.
Mode Switch Instruction:
Press fire button three times quickly to change between the four interfaces:
Constant power temperature control SS/NI/Ti.
Constant Voltage temperature control SS/NI/Ti.
Temperature Control Instructions:
Switching between Celcius and Ferenheit: When in Celcius mode, press the down button until you reach 100°C. Keep pressing down and the temperature will roll over to 600°F. When in Ferenheit mode, press the down button until you reach 200°F. Keep pressing down and the temperature will roll over to 315°C. Press and hold the button to engage auto- scroll accelerator.
Wattage Control in Temperature Control mode While in TC mode, press the fire button 4 times fast to get into wattage adjustment mode. You will see the letter W blinking. Press the up or down button to raise or lower the wattage. The available range of wattage adjustment is 5 to 80W.
D. Wattage Control Instruction:
The available range for wattage control is 5w- 222w.
Each adjustable step is 1 watt
Default love mode is 160w-222w.
a. The device can automatically recommend an optimum wattage for your atomizer’s resistance.
b. The LOVE mode can be turned on or off by the function menu.
E. Voltage regulation:
0. 5~ 7.5V adjustment step: 0.1 V.
a. The device can automatically recommend an optimum voltage for your atomizer’s resistance
b. You can switch between voltage and wattage modes in the function menu.
F. Combination key instruction:
a. Press up and down buttons at the same time for 1.5 Seconds to enter Function Menu Interface.
b. Press up and fire buttons at the same time for 1.5 Seconds to lock the device.
Press up and down buttons at the same time to unlock the device.
PS:
When the device is locked, the up, down, and fire buttons are not available. Press the fire button for vaping and combination key for operation.
c. Press the fire and down buttons at the same time for 1.5 Seconds to flip the screen orientation.
d. When in Custom mode under Power and Temperature control, press fire and down buttons at the same time for 1.5 Seconds to enter Custom per second.
G. Function Menu Instructions:
Press up and down buttons at same time for 1.55 to enter the function menu Interface, and press up or down button to choose the function and then press the fire button to make confirmation and go to the next step. Then you can make the adjustment by pressing up or down button. When you finish adjustment, press fire button 1.55 to confirm the adjustment and return to working interface
H. Custom Mode:
Press up button and down button at same time for 1.55 ,then go to the function menu Interface , and press up or down to choose the Custom Mode and then press fire button to go into custom mode Interface
Under Custom Mode, press fire button 3 times fast to switch sequentially between 4 types of custom modes: Power Mode, Temperature Control Mode 55316, Temperature Control Mode Ni200, and Temperature Control Mode Ti.
a. Press up and down buttons to switch sequentially between Mode M1 to M5.
b. Pressing the fire button 4 times will lead the device into Custom Mode: Customization for every second of the allowed time for inhalation (Under wattage custom mode, it will show the adjusted power value in the upper right corner; Under temperature control custom mode, it will display the adjusted TC value.) Press up and down buttons to raise or lower the settings manually. Press fire button to set the values and move to the next second. After adjusting the values for each second, press and hold the fire button for 1.5 seconds to confirm all settings and return to the Custom mode main interface.
Sleep Mode:
If there is no operation for 30 seconds, screen will turn off. If there is no operation for 3 minutes after the screen turns off, the device will enter sleep mode automatically. If the atomizer resistance changes before the device enters sleep mode, the screen will prompt you with the New Coil, YES/NO interface upon waking from sleep mode; If the atomizer resistance changes while the device is in sleep mode, the screen will not prompt you with the New Coil, YES/NO interface. Press any key to recover display from sleep mode.
J. Customization:
Users can change custom settings through computer firmware developed by Woody Vapes Inc., such as changing menu displays, adjusting temperature data, temperature curve and power curve etc. to customize the device to the user’s preferences the and reach the best taste.
K.
When the Alpha-I Box mods begin charging (Input Voltage must be about (5±0.5V) with USB connection), If there is no operation for 30 seconds the two battery icon will display on the screen, and the device will go into power saving mode (Reference Picture 1). If the batteries charge statuses are not the same, the two batteries charge icon will display each bettery individually. After both batteries are full, it will display both battery icons as full.
L. Using the PC APP to change the Temperature
Coefficient and select the temperature wire types:
You can use the PC App to select from 1 to 5 of the available TC modes, SS316, Ni200, Ti, NC, or TCR, and to raise or lower the Temperature Coefficient.
Coil advanced setting select
M. Function prompt:
Overtime protection: TIME OUT
Check new atomizer: NEW YES (+), COIL NO (-)
Low Battery: LOW POWER
Low Battery Voltage: CHECK BATTERY
Atomizer Short: ATOMIZER SHORT
Check Atomizer: CHECK ATOMIZER
High Resistance: HIGH ATOMIZER
Over Temp Protection: TEMP HIGH
Locked: LOCK
Unlock: UNLOCK
Turn off screen: OFF
N. Remark:
a. Under Power output at 222W, the supported atomizer resistance range is 0.1-0.25 ohm.
b. Charging Time: About 3 hours under 5V 2A Input.
c. Supports vaping while the device is charging (and also support adjust power, adjust temperature, switch mode, and combination function while the device is charging).
d. Requirement for the specification of battery: a). 18650 battery; discharge rate must be at least
35A.
b). Same brand, model and specification for two batteries
e. Suggested Battery Brand: Sony, Samsung.
f. Screen Size: 0.91 inch OLED.
g. Regulating Temperature control wire default Value:
Ni: 6000~7000 Standard Default Value: 6500 Adjusting Rate: Short press: 1, long Press: 10
Ti: 3500-4500 Standard Default Value: 4000 Adjusting Rate: Short press: 1, long Press: 10
SS: 1000-1600 Standard Default Value: 1300 Adjusting Rate: Short press: 1, long Press: 10
NC: 200-6OO Standard Default Value: 400 Adjusting Rate: Short press: 1, long Press: 10
TC: 100-7000 Standard Default Value: 1000 Adjusting Rate: Short press: 1, long Press: 10
PS: Tips:
1). Higher Accommodation coefficient of the TC wire, higher temperature.
2). Wire from different suppliers will be a little different from each other, please adjust the Temperature coefficient of the TC wire to get the best feeling for vaping.
3). Please adjust temperature slowly, or it may burn the cotton.
H. Regulating Temperature control wire calculated cooling.
Calculated cooling adjustable range: 0.05 to 1.50, Adjusting Rate: 0.0010.
This function is only available under temperature control mode.
The adjustable range is士20% of current resistance.
Notice
a. Because this product adopts SV rechargeable series circuits, and also it supports balance charging function, so the situation of heating during charging is a normal phenomenon
b. Please stay away from fire, water and high temperature.
c. Please use high rate discharge batteries, over 35A is recommended.
d. Please gently use this device; do not drop, damage or abuse the device, or drop it in water, etc.
e. Please make sure to use the right working mode for different atomizers.
f. Please don’t use batteries with broken skin or which are not completely insulated.